Schneider TM3DQ16UK Module TM3 - 16 Outputs Transistor NPN HE10
Product Description
Schneider TM3DQ16UK Module TM3 - 16 Outputs Transistor NPN HE10
Overview:
The Schneider TM3DQ16UK Module TM3 is an advanced and versatile industrial automation solution designed for precise control and efficient management of output devices. Boasting 16 outputs with transistor NPN (Negative-Positive-Negative) configuration, this module is an indispensable component for enhancing the performance and reliability of your industrial processes.
Technical Specifications:
- Output Configuration: 16 outputs with transistor NPN
- Voltage Rating: Suitable for a wide range of industrial voltage requirements
- Communication Interface: Seamless integration with industrial communication protocols
- Compact Design: The HE10 form factor ensures a space-efficient and streamlined installation
- Robust Construction: Built to withstand challenging industrial environments, providing long-term durability
- High Precision: Accurate and reliable control for a variety of applications
- Compatibility: Designed to seamlessly integrate with Schneider's comprehensive automation ecosystem
Key Features:
Optimized Performance: The TM3DQ16UK Module is engineered for optimal performance, providing precise and responsive control over 16 output channels. This is crucial for maintaining efficiency and accuracy in diverse industrial applications.
Flexible Voltage Compatibility: With a versatile voltage rating, this module accommodates a wide spectrum of industrial voltage requirements, offering adaptability to various operating conditions.
Industrial-Grade Reliability: The module's robust construction ensures reliability in harsh industrial environments. It is engineered to withstand challenging conditions, providing consistent performance over an extended operational life.
Seamless Integration: The HE10 form factor and compatibility with industrial communication protocols make integration with existing systems straightforward. This facilitates a smooth transition and ensures compatibility with Schneider's automation ecosystem.
Applications:
Manufacturing Processes: Enhance control and precision in manufacturing lines by integrating the TM3DQ16UK Module for optimal output management.
Process Automation: Streamline and improve various industrial processes by leveraging the module's high-precision control capabilities.
Industrial Machinery: Ensure reliable and efficient operation of industrial machinery by incorporating this advanced output control module.
Conclusion:
The Schneider TM3DQ16UK Module TM3 sets a new standard in industrial output control, offering unmatched precision, reliability, and versatility. With 16 outputs featuring transistor NPN technology, this module empowers industrial processes, providing a solid foundation for enhanced automation and control.
Invest in the Schneider TM3DQ16UK Module TM3 today to elevate your industrial automation to new heights.
range of product |
Modicon TM3
|
|
---|---|---|
product or component type |
Discrete output module
|
|
range compatibility |
Modicon M241
Modicon M221 Modicon M251 |
|
discrete output type |
Transistor
|
|
discrete output number |
16
|
|
discrete output logic |
Negative logic (sink)
|
|
discrete output voltage |
24 V DC for transistor output
|
|
discrete output current |
100 mA for transistor output
|
discrete I/O number |
16
|
|
---|---|---|
current consumption |
5 mA at 5 V DC via bus connector at state off
0 mA at 24 V DC via bus connector at state off 15 mA at 5 V DC via bus connector at state on 20 mA at 24 V DC via bus connector at state on |
|
response time |
450 µs for turn-on
450 µs for turn-off |
|
leakage current |
0.1 mA for transistor output
|
|
voltage drop |
0.4 V
|
|
local signalling |
1 LED per channel green for output status
|
|
electrical connection |
HE-10 connector for outputs
|
|
insulation |
500 V AC between output and internal logic
Non-insulated between outputs |
|
marking |
CE
|
|
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715 Plate or panel with fixing kit |
|
height |
90 mm
|
|
depth |
81.3 mm
|
|
width |
21.4 mm
|
|
product weight |
0.111 kg
|
standards |
EN/IEC 61010-2-201
EN/IEC 61131-2 |
|
---|---|---|
product certifications |
C-Tick
cULus |
|
resistance to electrostatic discharge |
4 kV (on contact) conforming to EN/IEC 61000-4-2
8 kV (in air) conforming to EN/IEC 61000-4-2 |
|
resistance to electromagnetic fields |
10 V/m at 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m at 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m at 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 |
|
resistance to magnetic fields |
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
|
|
resistance to fast transients |
1 kV for I/O conforming to EN/IEC 61000-4-4
|
|
surge withstand |
1 kV for I/O (DC) in common mode conforming to EN/IEC 61000-4-5
|
|
resistance to conducted disturbances |
10 Vrms at 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 Vrms at spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
|
electromagnetic emission |
Radiated emissions, test level: 40 dBμV/m QP with class A,
condition of test: 10 m (radio frequency: 30...230 MHz)
conforming to EN/IEC 55011
Radiated emissions, test level: 47 dBμV/m QP with class A, condition of test: 10 m (radio frequency: 230...1000 MHz) conforming to EN/IEC 55011 |
|
ambient air temperature for operation |
-10...55 °C for horizontal installation
-10...35 °C for vertical installation |
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
10...95 % without condensation in operation
10...95 % without condensation in storage |
|
IP degree of protection |
IP20 with protective cover in place
|
|
pollution degree |
2
|
|
operating altitude |
0...2000 m
|
|
storage altitude |
0...3000 m
|
|
vibration resistance |
3.5 mm (vibration frequency: 5...8.4 Hz) on DIN rail
3 gn (vibration frequency: 8.4...150 Hz) on DIN rail 3.5 mm (vibration frequency: 5...8.4 Hz) on panel 3 gn (vibration frequency: 8.4...150 Hz) on panel |
|
shock resistance |
15 gn (test wave duration:11 ms)
|
When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.
The total time it takes to receive your order is shown below:
The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.
Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.
Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.
Shipping from your local warehouse is significantly faster. Some charges may apply.
In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!