Schneider TM3TM3 Module - Dual Temperature Inputs and Analog Output

Product Description

Schneider TM3TM3 Module – Advanced Temperature Monitoring and Analog Output Solution

Optimize your industrial automation with the Schneider TM3TM3 Module, a versatile and high-performance component designed for precise temperature monitoring and reliable analog output control. This module is part of Schneider Electric’s TM3 series, known for its exceptional quality and robust functionality.

Key Features:

  • Dual Temperature Inputs: The TM3TM3 Module features two independent temperature inputs, allowing for accurate and simultaneous monitoring of two separate temperature points. These inputs support a range of temperature sensors, including thermocouples and RTDs, ensuring compatibility with various applications.

  • Single Analog Output: Equipped with a high-resolution analog output channel, the TM3TM3 Module provides precise control and adjustment based on temperature measurements. This output is ideal for applications requiring feedback to control devices such as valves or actuators.

  • High Accuracy and Reliability: Schneider Electric’s TM3TM3 Module is engineered to deliver high accuracy and reliability in temperature measurement and analog signal processing. This ensures consistent performance and dependable data, crucial for maintaining optimal operating conditions.

  • Seamless Integration: The TM3TM3 Module is designed for easy integration into Schneider Electric’s TM3 I/O system. Its compact form factor and straightforward installation process make it an excellent choice for expanding your automation system without complex modifications.

  • Robust Performance: Built to withstand demanding industrial environments, the TM3TM3 Module offers durable construction and reliable operation. It adheres to stringent quality standards, ensuring long-term performance and minimal maintenance requirements.

  • Advanced Diagnostics: The module includes diagnostic features that provide real-time status and error reporting, facilitating proactive maintenance and minimizing downtime.

Technical Specifications:

  • Temperature Input Channels: 2 (configurable for thermocouples or RTDs)
  • Analog Output Channel: 1 (0-10V, 4-20mA, or user-configurable)
  • Input Range: Wide range of temperature sensors supported
  • Accuracy: High precision measurement with minimal deviation
  • Power Supply: Compatible with standard industrial power supplies
  • Operating Temperature Range: Suitable for a wide range of industrial environments

Applications:

The Schneider TM3TM3 Module is ideal for a variety of applications including:

  • Process Control: Accurate temperature monitoring and control in manufacturing processes.
  • HVAC Systems: Ensuring optimal temperature regulation and system performance.
  • Environmental Monitoring: Reliable temperature data for environmental and climatic studies.
  • Industrial Automation: Enhancing the precision of automated systems and machinery.

Why Choose Schneider TM3TM3 Module?

The Schneider TM3TM3 Module combines cutting-edge technology with user-friendly features to provide a comprehensive solution for temperature measurement and analog output needs. Its high accuracy, robust construction, and seamless integration make it a valuable addition to any industrial automation system.

For more information and to purchase the Schneider TM3TM3 Module, contact us today or visit our website.

Main
range of product
Modicon TM3
product or component type
Input/output analog module
range compatibility
Modicon M221
Modicon M251
Modicon M241
analogue input number
2
analogue input type
Current, analogue input range: 4...20 mA
Current, analogue input range: 0...20 mA
Voltage, analogue input range: 0...10 V
Voltage, analogue input range: - 10...10 V
Thermocouple, analogue input range: - 200...1000 °C with thermocouple J
Thermocouple, analogue input range: - 200...1300 °C with thermocouple K
Thermocouple, analogue input range: 0...1760 °C with thermocouple R
Thermocouple, analogue input range: 0...1760 °C with thermocouple S
Thermocouple, analogue input range: 0...1820 °C with thermocouple B
Thermocouple, analogue input range: - 200...400 °C with thermocouple T
Thermocouple, analogue input range: - 200...1300 °C with thermocouple N
Thermocouple, analogue input range: - 200...800 °C with thermocouple E
Thermocouple, analogue input range: 0...2315 °C with thermocouple C
Ni 100/Ni 1000 temperature probe, analogue input range: - 60...180 °C
Pt 100 temperature probe, analogue input range: - 200...850 °C
Pt 1000 temperature probe, analogue input range: - 200...600 °C
analogue output number
1
analogue output type
4...20 mA current
0...20 mA current
0...10 V voltage
- 10...10 V voltage
Complementary
analogue input resolution
15 bits + sign
16 bits
permissible continuous overload
13 V voltage
40 mA current
input impedance
<= 50 Ohm current
>= 1 MOhm temperature probe
>= 1 MOhm thermocouple
>= 1 MOhm voltage
analogue output resolution
12 bits
LSB value
0.15 mV, analogue input: 0...10 V voltage
0.30 mV, analogue input: - 10...10 V voltage
0.30 µA, analogue input: 0...20 mA current
0.244 µA, analogue input: 4...20 mA current
0.1 °C temperature probe
2.44 mV, analogue output: 0...10 V voltage
4.88 mV, analogue output: - 10...10 V voltage
4.88 µA, analogue output: 0...20 mA current
3.91 µA, analogue output: 4...20 mA current
0.1 °C thermocouple
load type
Resistive
load impedance ohmic
1 kOhm voltage
300 Ohm current
stabilisation time
1 ms
conversion time
100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple
100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe
10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current
sampling duration
10 ms for analogue input voltage/current
100 ms for analogue input voltage/current
100 ms for analogue input thermocouple
100 ms for analogue input temperature probe
absolute accuracy error
+/- 0.1 % of full scale at 25 °C for analogue input voltage/current
+/- 0.1 % of full scale at 25 °C for analogue output voltage/current
+/- 0.1 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe
+/- 6 °C at 25 °C for thermocouple R, S 0...200 °C
+/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C
+/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C
+/- 0.1 % of full scale at 25 °C for thermocouple C 0...2315 °C
+/- 0.1 % of full scale at 25 °C for thermocouple R, S 200...1760 °C
+/- 0.1 % of full scale at 25 °C for thermocouple B 300...1820 °C
+/- 0.1 % of full scale at 25 °C for thermocouple K 0...1300 °C
+/- 0.1 % of full scale at 25 °C for thermocouple J 0...1000 °C
+/- 0.1 % of full scale at 25 °C for thermocouple E 0...800 °C
+/- 0.1 % of full scale at 25 °C for thermocouple T 0...400 °C
+/- 0.1 % of full scale at 25 °C for thermocouple N 0...1300 °C
temperature drift
+/- 0.006 %FS/°C
repeat accuracy
+/-0.5 %FS for input
+/- 0.4 %FS for output
non-linearity
+/- 0.01 %FS analog output
+/- 0.1 %FS analog input
output ripple
20 mV
cross talk
<= 1 LSB
[Us] rated supply voltage
24 V DC
supply voltage limits
20.4...28.8 V
type of cable
Twisted shielded pairs cable 30 m for input/output circuit
current consumption
55 mA at 24 V DC (no load) via external supply
55 mA at 5 V DC (no load) via bus connector
60 mA at 5 V DC (full load) via bus connector
80 mA at 24 V DC (full load) via external supply
local signalling
1 LED green for PWR
electrical connection
11 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for inputs, outputs and supply
insulation
500 V AC between output and internal logic
500 V AC between input and internal logic
1500 V AC between input and supply
1500 V AC between output and supply
marking
CE
surge withstand
1 kV for power supply with common mode protection conforming to EN/IEC 61000-4-5
0.5 kV for power supply with differential mode protection conforming to EN/IEC 61000-4-5
1 kV for I/O with common mode protection conforming to EN/IEC 61000-4-5
0.5 kV for I/O with differential mode protection conforming to EN/IEC 61000-4-5
mounting support
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
height
90 mm
depth
70 mm
width
23.6 mm
product weight
0.115 kg

Environment
standards
EN/IEC 61010-2-201
EN/IEC 61131-2
resistance to electrostatic discharge
4 kV on contact conforming to EN/IEC 61000-4-2
8 kV in air conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields
10 V/m at 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m at 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m at 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields
30 A/m conforming to EN/IEC 61000-4-8
resistance to fast transients
1 kV I/O conforming to EN/IEC 61000-4-4
resistance to conducted disturbances
10 V at 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V at spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
electromagnetic emission
Radiated emissions, test level: 40 dBμV/m QP class A (10 m at 30...230 MHz) conforming to EN/IEC 55011
Radiated emissions, test level: 47 dBμV/m QP class A (10 m at 230...1000 MHz) conforming to EN/IEC 55011
immunity to microbreaks
10 ms
ambient air temperature for operation
-10...55 °C (horizontal installation)
-10...35 °C (vertical installation)
ambient air temperature for storage
-25...70 °C
relative humidity
10...95 % without condensation in operation
10...95 % without condensation in storage
IP degree of protection
IP20
pollution degree
2
operating altitude
0...2000 m
storage altitude
0...3000 m
vibration resistance
3.5 mm at 5...8.4 Hz with DIN rail mounting support
3 gn at 8.4...150 Hz with DIN rail mounting support
shock resistance
15 gn during 11 ms

Write a review

Please login or register to review

When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.

The total time it takes to receive your order is shown below:

The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.

Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.

Shipping from your local warehouse is significantly faster. Some charges may apply.

In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!

Size Chart