Schneider TSXCTY4A 4 Channels Counter Module - 40 kHz, 36 mA at 24 V DC, 330 mA at 5 V DC

Schneider TSXCTY4A 4 Channels Counter Module - 40 kHz, 36 mA at 24 V DC, 330 mA at 5 V DC

0 reviews 0 sold. Only 1000 remain
Brand:
Product Code: TSXCTY4A
Availability: 1000
Viewed 1204 times

Product Description

Schneider TSXCTY4A 4 Channels Counter Module

Overview:

The Schneider TSXCTY4A 4 Channels Counter Module is engineered to provide high-precision counting capabilities for advanced industrial automation applications. Designed for use with Schneider Electric's Modicon TSX Micro PLC systems, this module integrates seamlessly into automation setups requiring reliable, high-speed counting operations.

Key Features:

  • High-Speed Counting: The TSXCTY4A supports a maximum counting frequency of 40 kHz, ensuring accurate and timely data acquisition for high-speed processes and applications.

  • Versatile Input Specifications: With four independent counting channels, this module is capable of handling diverse input signals, making it ideal for complex automation systems that require simultaneous monitoring of multiple processes.

  • Power Consumption: The module operates with a low current consumption of 36 mA at 24 V DC and 330 mA at 5 V DC, offering efficient power usage while maintaining high performance.

  • Compact and Robust Design: The Schneider TSXCTY4A is designed with a compact footprint, facilitating easy integration into space-constrained control panels without compromising on durability or performance.

  • Flexible Application Use: Ideal for use in various industrial environments, including manufacturing, process control, and machine automation, where precise counting and data acquisition are critical.

Technical Specifications:

  • Channels: 4
  • Maximum Counting Frequency: 40 kHz
  • Current Consumption:
    • 36 mA at 24 V DC
    • 330 mA at 5 V DC
  • Compatibility: Compatible with Schneider Electric’s Modicon TSX Micro PLC systems

Applications:

The Schneider TSXCTY4A module is perfect for applications requiring high-speed counting such as:

  • Production line counters
  • Batch process monitoring
  • Machine cycle counting
  • Event logging in complex automation systems

Benefits:

  • Enhanced Precision: Achieve accurate and reliable counting even at high frequencies, improving overall process efficiency.
  • Reduced Power Consumption: Lower operational costs with optimized power use.
  • Seamless Integration: Easily integrates into existing PLC systems, reducing installation time and complexity.

Why Choose Schneider TSXCTY4A?

The Schneider TSXCTY4A 4 Channels Counter Module stands out for its reliability, high-speed performance, and efficiency. Its design ensures compatibility with a wide range of industrial applications, making it a valuable component in any advanced automation system.

Main
range of product
Modicon Premium Automation platform
product or component type
Counter modules
I/O modularity
4 channels
electrical circuit type
Auxiliary output conforming to EN/IEC 61131
Complementary
counting frequency
40 kHz
power dissipation in W
8...11.5 W
cycle time
10 ms
discrete input logic
Current sink auxiliary input (preset, enable and read) conforming to IEC 1131 Type 2
Resistive 2/3-wire proximity sensors PNP/NPN conforming to IEC 1131 Type 2
Resistive encoder input
input logic
Positive
input compatibility
Incremental encoder 10...30 V totem pole
Incremental encoder 5 V DC RS422
input voltage
24 V 18 mA 2/3-wire proximity sensors PNP/NPN
24 V 7 mA auxiliary input (preset, enable and read)
5 V 18 mA encoder input
input voltage limits
<= 5.5 V encoder input
19...30 V 2/3-wire proximity sensors PNP/NPN
19...30 V auxiliary input (preset, enable and read)
voltage state 1 guaranteed
>= 11 V 2/3-wire proximity sensors PNP/NPN
>= 11 V auxiliary input (preset, enable and read)
>= 2.4 V encoder input
current state 1 guaranteed
>= 3.7 mA encoder input
>= 6 mA 2/3-wire proximity sensors PNP/NPN
>= 6 mA auxiliary input (preset, enable and read)
voltage state 0 guaranteed
<= 1.2 V encoder input
<= 5 V 2/3-wire proximity sensors PNP/NPN
<= 5 V auxiliary input (preset, enable and read)
current state 0 guaranteed
<= 1 mA encoder input
<= 2 mA 2/3-wire proximity sensors PNP/NPN
<= 2 mA auxiliary input (preset, enable and read)
response time
< 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset, enable and read)
input impedance
> 270 Ohm at U = 2.4 V encoder input
1400 Ohm at Un 2/3-wire proximity sensors PNP/NPN
3400 Ohm at Un auxiliary input (preset, enable and read)
400 Ohm at Un encoder input
output voltage
24 V DC
nominal output current
0.5 A
output voltage limits
19...30 V
voltage drop
< 0.5 V at state 1
output compatibility
Positive logic DC inputs (resistance <= 15 kOhm) auxiliary output
leakage current
< 0.1 mA
switching frequency
< 0.6/LI² Hz on inductive load
output overload protection
Current limiter
Thermal tripping via program or automatically
output short-circuit protection
Current limiter
Thermal tripping via program or automatically
output overvoltage protection
Zener diode
reverse polarity protection
Reverse diode on supply
checks
Sensor power supply
current consumption
330 mA 5 V DC
36 mA 24 V DC
module format
Standard
local signalling
4 LEDs green axis diagnostics available (CH.)
1 LED green module operating (RUN)
1 LED red external fault (I/O)
1 LED red internal fault, module failure (ERR)
electrical connection
2 connectors HE-10 20 pins
4 connectors SUB-D 15
product weight
0.43 kg

Environment
protective treatment
TC
ambient air temperature for operation
0...60 °C
ambient air temperature for storage
-25...70 °C
relative humidity
5...95 % without condensation
operating altitude
<= 2000 m

Write a review

Please login or register to review

When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.

The total time it takes to receive your order is shown below:

The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.

Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.

Shipping from your local warehouse is significantly faster. Some charges may apply.

In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!

Size Chart