Schneider TSXCTY4A 4 Channels Counter Module - 40 kHz, 36 mA at 24 V DC, 330 mA at 5 V DC
Product Description
Schneider TSXCTY4A 4 Channels Counter Module
Overview:
The Schneider TSXCTY4A 4 Channels Counter Module is engineered to provide high-precision counting capabilities for advanced industrial automation applications. Designed for use with Schneider Electric's Modicon TSX Micro PLC systems, this module integrates seamlessly into automation setups requiring reliable, high-speed counting operations.
Key Features:
High-Speed Counting: The TSXCTY4A supports a maximum counting frequency of 40 kHz, ensuring accurate and timely data acquisition for high-speed processes and applications.
Versatile Input Specifications: With four independent counting channels, this module is capable of handling diverse input signals, making it ideal for complex automation systems that require simultaneous monitoring of multiple processes.
Power Consumption: The module operates with a low current consumption of 36 mA at 24 V DC and 330 mA at 5 V DC, offering efficient power usage while maintaining high performance.
Compact and Robust Design: The Schneider TSXCTY4A is designed with a compact footprint, facilitating easy integration into space-constrained control panels without compromising on durability or performance.
Flexible Application Use: Ideal for use in various industrial environments, including manufacturing, process control, and machine automation, where precise counting and data acquisition are critical.
Technical Specifications:
- Channels: 4
- Maximum Counting Frequency: 40 kHz
- Current Consumption:
- 36 mA at 24 V DC
- 330 mA at 5 V DC
- Compatibility: Compatible with Schneider Electric’s Modicon TSX Micro PLC systems
Applications:
The Schneider TSXCTY4A module is perfect for applications requiring high-speed counting such as:
- Production line counters
- Batch process monitoring
- Machine cycle counting
- Event logging in complex automation systems
Benefits:
- Enhanced Precision: Achieve accurate and reliable counting even at high frequencies, improving overall process efficiency.
- Reduced Power Consumption: Lower operational costs with optimized power use.
- Seamless Integration: Easily integrates into existing PLC systems, reducing installation time and complexity.
Why Choose Schneider TSXCTY4A?
The Schneider TSXCTY4A 4 Channels Counter Module stands out for its reliability, high-speed performance, and efficiency. Its design ensures compatibility with a wide range of industrial applications, making it a valuable component in any advanced automation system.
range of product |
Modicon Premium Automation platform
|
|
---|---|---|
product or component type |
Counter modules
|
|
I/O modularity |
4 channels
|
|
electrical circuit type |
Auxiliary output conforming to EN/IEC 61131
|
counting frequency |
40 kHz
|
|
---|---|---|
power dissipation in W |
8...11.5 W
|
|
cycle time |
10 ms
|
|
discrete input logic |
Current sink auxiliary input (preset, enable and read)
conforming to IEC 1131 Type 2
Resistive 2/3-wire proximity sensors PNP/NPN conforming to IEC 1131 Type 2 Resistive encoder input |
|
input logic |
Positive
|
|
input compatibility |
Incremental encoder 10...30 V totem pole
Incremental encoder 5 V DC RS422 |
|
input voltage |
24 V 18 mA 2/3-wire proximity sensors PNP/NPN
24 V 7 mA auxiliary input (preset, enable and read) 5 V 18 mA encoder input |
|
input voltage limits |
<= 5.5 V encoder input
19...30 V 2/3-wire proximity sensors PNP/NPN 19...30 V auxiliary input (preset, enable and read) |
|
voltage state 1 guaranteed |
>= 11 V 2/3-wire proximity sensors PNP/NPN
>= 11 V auxiliary input (preset, enable and read) >= 2.4 V encoder input |
|
current state 1 guaranteed |
>= 3.7 mA encoder input
>= 6 mA 2/3-wire proximity sensors PNP/NPN >= 6 mA auxiliary input (preset, enable and read) |
|
voltage state 0 guaranteed |
<= 1.2 V encoder input
<= 5 V 2/3-wire proximity sensors PNP/NPN <= 5 V auxiliary input (preset, enable and read) |
|
current state 0 guaranteed |
<= 1 mA encoder input
<= 2 mA 2/3-wire proximity sensors PNP/NPN <= 2 mA auxiliary input (preset, enable and read) |
|
response time |
< 2.5 ms sensor voltage at loss of 24 V auxiliary input (preset,
enable and read)
|
|
input impedance |
> 270 Ohm at U = 2.4 V encoder input
1400 Ohm at Un 2/3-wire proximity sensors PNP/NPN 3400 Ohm at Un auxiliary input (preset, enable and read) 400 Ohm at Un encoder input |
|
output voltage |
24 V DC
|
|
nominal output current |
0.5 A
|
|
output voltage limits |
19...30 V
|
|
voltage drop |
< 0.5 V at state 1
|
|
output compatibility |
Positive logic DC inputs (resistance <= 15 kOhm) auxiliary
output
|
|
leakage current |
< 0.1 mA
|
|
switching frequency |
< 0.6/LI² Hz on inductive load
|
|
output overload protection |
Current limiter
Thermal tripping via program or automatically |
|
output short-circuit protection |
Current limiter
Thermal tripping via program or automatically |
|
output overvoltage protection |
Zener diode
|
|
reverse polarity protection |
Reverse diode on supply
|
|
checks |
Sensor power supply
|
|
current consumption |
330 mA 5 V DC
36 mA 24 V DC |
|
module format |
Standard
|
|
local signalling |
4 LEDs green axis diagnostics available (CH.)
1 LED green module operating (RUN) 1 LED red external fault (I/O) 1 LED red internal fault, module failure (ERR) |
|
electrical connection |
2 connectors HE-10 20 pins
4 connectors SUB-D 15 |
|
product weight |
0.43 kg
|
protective treatment |
TC
|
|
---|---|---|
ambient air temperature for operation |
0...60 °C
|
|
ambient air temperature for storage |
-25...70 °C
|
|
relative humidity |
5...95 % without condensation
|
|
operating altitude |
<= 2000 m
|
When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.
The total time it takes to receive your order is shown below:
The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.
Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.
Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.
Shipping from your local warehouse is significantly faster. Some charges may apply.
In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!