Delta DVP01LC-SL Load Cell Module 1 channel, 24 bit RS-485

Delta DVP01LC-SL Load Cell Module 1 channel, 24 bit RS-485

0 reviews 0 sold. Only 1000 remain
Brand:
Product Code: DVP01LC-SL
Availability: 1000
Viewed 1862 times

Product Description

Delta DVP01LC-SL Load Cell Module 1 Channel, 24-bit RS-485

The Delta DVP01LC-SL Load Cell Module is an exceptional precision instrument engineered to deliver unparalleled performance in weight measurement and control systems. This cutting-edge 1-channel module employs state-of-the-art technology, boasting a 24-bit RS-485 interface, ensuring superior accuracy and reliability in various industrial applications.

Key Features:

  • High-Precision Load Measurement: With a 24-bit resolution, this module offers an incredibly high level of accuracy, capturing even the most minute changes in load with exceptional precision.

  • Versatile Connectivity: Utilizing the RS-485 interface, the module facilitates seamless communication with a wide range of systems and devices, ensuring compatibility and easy integration into diverse setups.

  • Robust Build Quality: Crafted with durability in mind, the Delta DVP01LC-SL Load Cell Module is designed to withstand challenging industrial environments, maintaining accuracy and reliability even in harsh conditions.

  • Single Channel Efficiency: This module's single-channel design allows for focused and efficient load monitoring, streamlining processes and enhancing productivity.

Applications:

  • Industrial Automation: Perfect for integration into industrial automation systems for precise load monitoring and control in manufacturing, packaging, and logistics.

  • Weighing Systems: Ideal for incorporation into weighing systems for applications in transportation, agriculture, and laboratory environments where accurate weight measurement is paramount.

  • Process Control: Enables precise load control in processes requiring accurate weight monitoring, ensuring optimal quality and efficiency.

Technical Specifications:

  • Channels: 1
  • Interface: RS-485
  • Resolution: 24-bit
  • Compatibility: Compatible with a wide range of load cells and systems
  • Operating Conditions: Designed to perform reliably in varied industrial environments

Why Choose Delta DVP01LC-SL Load Cell Module?

Engineered with a focus on precision, reliability, and seamless integration, the Delta DVP01LC-SL Load Cell Module stands as an industry-leading solution for accurate load measurement and control. Its cutting-edge technology and robust construction make it the preferred choice for industries seeking uncompromised accuracy and efficiency in their operations.

Enhance your industrial processes with the Delta DVP01LC-SL Load Cell Module - a testament to Delta's commitment to excellence in precision instrumentation.

For inquiries, technical specifications, and pricing, please contact us.

Delta DVP01LC-SL Load Cell Module 1 channel, 24 bit RS-485

Electrical Specifications

Load cell module

Voltage output

Rated power supply voltage/ power consumption

24 VDC (-15 to +20%) / 3W

Voltage Boundary

18 to 31.2 VDC

Max. current consumption

125 mA

Input signal range

± 40 mVDC

Sensibility

+5 VDC +/-10%

Internal resolution

24 bits

Communication port

RS-232, RS-485

Applicable sensor type

4-wire or 6-wire strain gauge

Temperature coefficient span

≤ ± 50 ppm/K v. E

Temperature coefficient zero point

≤ ± 0.4 μV/K

Linearity error

≤ 0.02%

Response time

2, 10, 20, 40, 80 ms × channels

4 measuring ranges

0 to 1 mV/V, 0 to 2 mV/V, 0 to 4 mV/V, 0 to 6mV/V

Max. distance for connecting to load cell

100 M

Max. current output

5VDC * 300 mA

Permitted load cell resistance

40 to 4,010 Ω

Common mode rejection (CMRR @50/60 Hz)

≥100dB

Dynamic value filter

Setting range: K1 to K5

Average value filter

Setting range: K1 to K100

Isolation method

500 VAC between digital circuits and Ground

500 VAC between analog circuits and Ground

500 VAC between analog circuits and digital circuits

Series connection to DVP-PLC MPU

Connectable to the left side of MPU, numbered from 100 to 107 according to the position of module from the closest to farthest to MPU.

Operation / storage temperature

Operation: 0 to 55°C (temp.), 50 to 95% (humidity), pollution degree 2

Storage: -25 to 70°C (temp.), 5 to 95% (humidity)

Vibration / shock immunity

International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/

IEC61131-2 & IEC 68-2-27 (TEST Ea)

*Complying with DIN1319-1, the tolerance of measured value should be <=0.05% under 200C + 10K temperature range.

Write a review

Please login or register to review

When you order from opencartworks.com, you will receive a confirmation email. Once your order is shipped, you will be emailed the tracking information for your order's shipment. You can choose your preferred shipping method on the Order Information page during the checkout process.

The total time it takes to receive your order is shown below:

The total delivery time is calculated from the time your order is placed until the time it is delivered to you. Total delivery time is broken down into processing time and shipping time.

Processing time: The time it takes to prepare your item(s) to ship from our warehouse. This includes preparing your items, performing quality checks, and packing for shipment.

Shipping time: The time for your item(s) to tarvel from our warehouse to your destination.

Shipping from your local warehouse is significantly faster. Some charges may apply.

In addition, the transit time depends on where you're located and where your package comes from. If you want to know more information, please contact the customer service. We will settle your problem as soon as possible. Enjoy shopping!

Size Chart