<= 150 m (unshielded cable) motor: 0.75...11 kW 380...480 V,
with 1 filter
<= 150 m (shielded cable) motor: 0.75...4 kW 380...480 V, with 1
filter
<= 300 m (shielded cable) motor: 5.5...11 kW 380...480 V, with 2
filter
<= 500 m (unshielded cable) motor: 0.75...4 kW 380...480 V, with
2 filter
<= 500 m (unshielded cable) motor: 5.5...11 kW 380...480 V, with
1 filter + VW3A5502
<= 500 m (shielded cable) motor: 0.75...4 kW 380...480 V, with 2
filter
<= 1000 m (unshielded cable) motor: 0.75...5.5 kW 380...480 V,
with 1 filter + VW3A5502
<= 150 m (unshielded cable) motor: 0.75...5.5 kW 200...240 V,
with 1 filter
<= 150 m (shielded cable) motor: 0.75...4 kW 200...240 V, with 1
filter
<= 300 m (shielded cable) motor: 5.5 kW 200...240 V, with 2
filter
<= 500 m (unshielded cable) motor: 0.75...4 kW 200...240 V, with
2 filter
<= 500 m (unshielded cable) motor: 5.5 kW 200...240 V, with 1
filter + VW3A5502
<= 500 m (shielded cable) motor: 0.75...4 kW 200...240 V, with 2
filter
<= 1000 m (unshielded cable) motor: 0.75...4 kW 200...240 V,
with 1 filter + VW3A5502
|